This chapter describes the hot-socketing feature, power-on reset (POR) requirements, and their implemen-
tation in Cyclone V devices.
Related Information
Cyclone V Device Handbook: Known Issues
Lists the planned updates to the Cyclone V Device Handbook chapters.
PowerPlay Power Analysis
Provides more information about the Quartus
Cyclone V Device Datasheet
Provides more information about the recommended operating conditions of each power supply.
Cyclone V Device Family Pin Connection Guidelines
Provides detailed information about power supply pin connection guidelines and power regulator sharing.
Board Design Resource Center
Provides detailed information about power supply design requirements.

Power Consumption

The total power consumption of a Cyclone V device consists of the following components:
Static power—the power that the configured device consumes when powered up but no clocks are
operating.
Dynamic power— the additional power consumption of the device due to signal activity or toggling.

Dynamic Power Equation

Figure 10-1: Dynamic Power
The following equation shows how to calculate dynamic power where P is power, C is the load capacitance,
and V is the supply voltage level.
2014 Altera Corporation. All rights reserved. ALTERA, ARRIA, CYCLONE, HARDCOPY, MAX, MEGACORE, NIOS, QUARTUS and STRATIX words
and logos are trademarks of Altera Corporation and registered in the U.S. Patent and Trademark Office and in other countries. All other
words and logos identified as trademarks or service marks are the property of their respective holders as described at
www.altera.com/common/legal.html. Altera warrants performance of its semiconductor products to current specifications in accordance with
Altera's standard warranty, but reserves the right to make changes to any products and services at any time without notice. Altera assumes
no responsibility or liability arising out of the application or use of any information, product, or service described herein except as expressly
agreed to in writing by Altera. Altera customers are advised to obtain the latest version of device specifications before relying on any published
information and before placing orders for products or services.
www.altera.com
101 Innovation Drive, San Jose, CA 95134

Power Management in Cyclone V Devices

Send Feedback
®
II PowerPlay Power Analyzer tool.