Using Error Detection Features In User Mode; Enabling Error Detection - Altera Cyclone V Device Handbook

Hide thumbs Also See for Cyclone V:
Table of Contents

Advertisement

8-4

Using Error Detection Features in User Mode

Table 8-3: CRC Calculation Time in Cyclone V Devices
The following table lists the minimum and maximum time taken to calculate the CRC value:
The minimum time is derived using the maximum clock frequency with a divisor of 0.
The maximum time is derived using the minimum clock frequency with a divisor of 8.
Variant
Cyclone E
Cyclone V GX
Cyclone V GT
Cyclone V SE
Cyclone V SX
Cyclone V ST
Using Error Detection Features in User Mode
This section describes the pin, registers, process flow, and procedures for error detection in user mode.

Enabling Error Detection

To enable user mode error detection in the Quartus II software, follow these steps:
1. On the Assignments menu, click Device.
2. In the Device dialog box, click Device and Pin Options.
Altera Corporation
Member Code
Minimum Time (ms)
A2
A4
A5
A7
A9
C3
C4
C5
C7
C9
D5
D7
D9
A2
A4
A5
A6
C4
C5
C6
D5
D6
4
4
7
7
15
8
7
7
7
15
7
7
15
7
7
13
13
7
13
13
13
13
SEU Mitigation for Cyclone V Devices
2013.11.12
Maximum Time (s)
2.08
2.08
3.54
3.62
7.40
4.05
3.54
3.54
3.62
7.40
3.54
3.62
7.40
3.59
3.59
6.30
6.30
3.59
6.30
6.30
6.30
6.30
Send Feedback