cv_54011
2013.12.30
• The response timeout field (response_timeout) of the tmout register. A typical value is 0x64.
• The data timeout field (data_timeout) of the tmout register, highest of the following:
• 10 * N
N
= 10 * ((TAAC * F
where:
TAAC = Time-dependent factor of the data access time
F
NSAC = Worst-case clock rate-dependent factor of the data access time
• Host FIFO buffer latency
On read: Time elapsed before host starts reading from a full FIFO buffer
On write: Time elapsed before host starts writing to an empty FIFO buffer
• Debounce counter register (debnce). A typical debounce value is 25 ms.
• TX watermark field (tx_wmark) of the FIFO threshold watermark register (fifoth). Typically,
the threshold value is set to 512, which is half the FIFO buffer depth.
• RX watermark field (rx_wmark) of the fifoth register. Typically, the threshold value is set to
511.
These registers do not need to be changed with every SD/MMC/CE-ATA command. Set them to a typical
value according to the SD/MMC/CE-ATA specifications.
Related Information
Clock Setup
Refer to this section for information on setting the clock source assignments.
Enumerated Card Stack
Refer to this section for information on discovering the card stack according to the card type.
Enumerated Card Stack
The card stack performs the following tasks:
• Discovers the connected card
• Sets the relative Card Address Register (RCA) in the connected card
• Reads the card specific information
• Stores the card specific information locally
The card connected to the controller can be an MMC, CE-ATA, SD or SDIO (including IO ONLY, MEM
ONLY and COMBO) card.
Identifying the Connected Card Type
To identify the connected card type, the following discovery sequence is needed:
1. Reset the card width 1 or 4 bit (card_width2) and card width 8 bit (card_width1) fields in the
ctype register to 0.
2. Identify the card type as SD, MMC, SDIO or SDIO-COMBO:
SD/MMC Controller
Send Feedback
AC
= card device total access time
AC
) + (100 * NSAC))
OP
= The card clock frequency used for the card operation
OP
on page 11-34
on page 11-31
Enumerated Card Stack
11-31
Altera Corporation