RX13T Group
9.2.13

Main Clock Oscillator Forced Oscillation Control Register (MOFCR)

Address(es): 0008 C293h
b7
b6
MOSEL MODR
0
0
Value after reset:
Bit
Symbol
b4 to b0
b5
MODRV21
b6
MOSEL
b7
Note:
Set the PRCR.PRC1 bit to 1 (write enabled) before rewriting this register.
MODRV21 Bit (Main Clock Oscillator Drive Capability Switch)
These bits select the drive capability of the main clock oscillator.
MOSEL Bit (Main Clock Oscillator Switch)
This bit selects the oscillation source of the main clock oscillator.
R01UH0822EJ0100 Rev.1.00
Jul 31, 2019
b5
b4
b3
b2
V21
0
0
0
0
Bit Name
Reserved
Main Clock Oscillator Drive
Capability Switch
Main Clock Oscillator Switch
Reserved
b1
b0
0
0
Description
These bits are read as 0. The write value should be 0.
0: 1 MHz or higher and lower than 10 MHz
1: 10 MHz to 20 MHz
0: Resonator
1: External oscillator input
This bit is read as 0. The write value should be 0.