Timer Output Master Enable Register (Toera) - Renesas RX100 Series User Manual

32-bit mcu
Hide thumbs Also See for RX100 Series:
Table of Contents

Advertisement

RX13T Group
19.2.20

Timer Output Master Enable Register (TOERA)

Address(es): MTU.TOERA 0009 520Ah
b7
b6
Value after reset:
1
1
Bit
Symbol
Bit Name
b0
OE3B
Master Enable MTIOC3B
b1
OE4A
Master Enable MTIOC4A
b2
OE4B
Master Enable MTIOC4B
b3
OE3D
Master Enable MTIOC3D
b4
OE4C
Master Enable MTIOC4C
b5
OE4D
Master Enable MTIOC4D
b7, b6
Reserved
Note 1. To output the inactive level from each pin when the MTU output is set to disabled, first set the data direction register (PDR) and
port output data register (PODR) of I/O ports to output the inactive level from general I/O ports, and then set the port mode
register (PMR) to use general I/O ports. For details, refer to section 17, I/O Ports.
TOERA enables or disables output settings for output pins MTIOC4D, MTIOC4C, MTIOC3D, MTIOC4B, MTIOC4A,
and MTIOC3B.
These pins do not output correctly if the bits in the TOERA register have not been set. In MTU3 and MTU4, set TOERA
prior to setting TIOR.
Set MTU.TOERA after setting the CST3 and CST4 bits in MTU.TSTRA to 0 (refer to Figure 19.42 and Figure 19.45 ).
R01UH0822EJ0100 Rev.1.00
Jul 31, 2019
b5
b4
b3
b2
OE4D
OE4C
OE3D
OE4B
0
0
0
0
19. Multi-Function Timer Pulse Unit 3 (MTU3c)
b1
b0
OE4A
OE3B
0
0
Description
0: MTU output is disabled*
1: MTU output is enabled
0: MTU output is disabled*
1: MTU output is enabled
0: MTU output is disabled*
1: MTU output is enabled
0: MTU output is disabled*
1: MTU output is enabled
0: MTU output is disabled*
1: MTU output is enabled
0: MTU output is disabled*
1: MTU output is enabled
These bits are read as 1. The write value should be 1.
1
1
1
1
1
1
Page 362 of 1041
R/W
R/W
R/W
R/W
R/W
R/W
R/W