Procedure To Receive The Mcu Information - Renesas RX100 Series User Manual

32-bit mcu
Hide thumbs Also See for RX100 Series:
Table of Contents

Advertisement

RX13T Group
31.11.2

Procedure to Receive the MCU Information

Procedure to send inquiry commands, and receive the information necessary to send setting commands, program/erase
commands, and read-check commands is as follows.
(1) Send a support device inquiry command (20h) to check what type of endianness the MCU supports. The MCU
returns all device codes and series names that it supports.
(2) Send a user area information inquiry command (25h) to check the start and end addresses of the user area. The
MCU returns the start and end addresses of the user area.
(3) Send a block information inquiry command (26h) to check the block configuration. The MCU returns the start
address, the size of one block, and the number of blocks for the user area and data area.
(4) Send a data area information inquiry command (2Bh) to check the start and end addresses of the data area. The
MCU returns the start and end addresses of the data area.
Serial
programmer
Figure 31.29
Procedure to Receive the MCU Information
R01UH0822EJ0100 Rev.1.00
Jul 31, 2019
20h (support device inquiry command)
Response to the support device inquiry command
25h (user area information inquiry command)
Response to the user area information inquiry command
26h (block information inquiry command)
Response to the block information inquiry command
2Bh (data area information inquiry command)
Response to the data area information inquiry command
31. Flash Memory (FLASH)
MCU
(1)
(2)
(3)
(4)