Renesas RX100 Series User Manual page 473

32-bit mcu
Hide thumbs Also See for RX100 Series:
Table of Contents

Advertisement

RX13T Group
Table 19.63
Interrupt Sources and A/D Converter Start Request Signals
Target Registers
MTU0.TGRA and MTU0.TCNT
MTU1.TGRA and MTU1.TCNT
MTU2.TGRA and MTU2.TCNT
MTU3.TGRA and MTU3.TCNT
MTU4.TGRA and MTU4.TCNT
MTU4.TCNT
MTU0.TGRE and MTU0.TCNT
MTU4.TADCORA and MTU4.TCNT
MTU4.TADCORB and MTU4.TCNT
MTU4.TADCORA and MTU4.TCNT,
MTU4.TADCORB and MTU4.TCNT
Note 1. Since PWM waveforms are generated in complementary PWM mode, MTU4.TGRA compare match not only with MTU4.TCNT
but also with MTU3.TCNT and TCNTSA is detected. Accordingly, when compare match with MTU3.TCNT and TCNTSA occurs,
TRGA4N is also generated.
When MTU3 and MTU 4 are made to operate in complementary PWM mode for generating an A/D converter start request, use
the A/D converter start request by compare match between MTU4.TCNT and MTU4.TADCORA/TADCORB.
R01UH0822EJ0100 Rev.1.00
Jul 31, 2019
Interrupt Source
Input capture/compare match
*1
MTU4.TCNT trough in complementary PWM mode
Compare match
Compare match (interrupt skipping function 2)
19. Multi-Function Timer Pulse Unit 3 (MTU3c)
A/D Converter Start Request Signal
TRGA0N
TRGA1N
TRGA2N
TRGA3N
TRGA4N
TRG0N
TRG4AN
TRG4BN
TRG4ABN