RX13T Group
(3) TCIV and TCIU Interrupt Timing
Figure 19.120 shows the TCIV interrupt request signal timing when an overflow is generated.
Figure 19.121 shows the TCIU interrupt request signal timing when an underflow is generated.
TCNT count clock
TCNT (overflow)
Overflow signal
Interrupt signal
Figure 19.120
TCIV Interrupt Timing
TCNT count clock
TCNT (underflow)
Underflow signal
Interrupt signal
Figure 19.121
TCIU Interrupt Timing
R01UH0822EJ0100 Rev.1.00
Jul 31, 2019
PCLKB
FFFFh
PCLKB
0000h
19. Multi-Function Timer Pulse Unit 3 (MTU3c)
0000h
FFFFh
Page 482 of 1041