Renesas RX100 Series User Manual page 861

32-bit mcu
Hide thumbs Also See for RX100 Series:
Table of Contents

Advertisement

RX13T Group
Operation example 4 shows group priority operation in group scan mode (ADGSPCR.GBRSCN = 0, ADGSPCR.GBRP
= 0, ADGSPCR.LGRRS = 0) when channel 0 is selected for group A and channels 1 to 3 are selected for group B.
Operation example 4: Group A trigger input during group B scan, without rescan setting
(1) When a group B trigger input sets the ADCSR.ADST bit to 1 (A/D conversion start), scan for the ANn channels of
group B selected in the ADANSB0 register, starts from the channel with the smallest number n.
(2) On completion of A/D conversion on a single channel, the result is stored in the corresponding A/D data register
(ADDRy).
(3) If a group A trigger is input during scan for group B, group B scan is discontinued while the ADCSR.ADST bit
remains 1, and scan for the ANn channels of group A selected in the ADANSA0 register, starts from the channel
with the smallest number n.
If A/D conversion is not completed when scan was discontinued, the result is not stored in the corresponding A/D
data register (ADDRy).
(4) On completion of A/D conversion on a single channel, the result is stored in the corresponding A/D data register
(ADDRy).
(5) After scan for group A is completed, a scan end interrupt request is generated if the ADCSR.ADIE bit is 1 (interrupt
generation upon scanning completion enabled).
(6) The ADST bit is automatically cleared to 0 when scan for group A is completed, and the 12-bit A/D converter enters
a wait state. Scan for group B is not started until the next group B trigger is input.
Trigger for
group A
Trigger for
group B
ADST
Group A
Channel 0
(AN000)
Group B
Channel 1
Waiting for conversion
(AN001)
Channel 2
(AN002)
Channel 3
(AN003)
ADDR0
ADDR1
ADDR2
ADDR3
Scan end
interrupt
Group B Scan end
Interrupt
Figure 26.19
Example 4 of Group Priority Operation: Group A Trigger Input during Group B Scan, Without
Rescan Setting (ADGSPCR.GBRSCN = 0, ADGSPCR.GBRP = 0, ADGSPCR.LGRRS = 0)
R01UH0822EJ0100 Rev.1.00
Jul 31, 2019
Group B scanned
(Group B is activated by a group B trigger)
A/D conversion
started
(1)
Waiting for conversion
A/D conversion B1
Waiting for conversion
Waiting for conversion
Stored
(2)
Waiting for conversion
A/D conversion B2
A/D conversion B3
A/D conversion result B1
Stored
(2)
26. 12-Bit A/D Converter (S12ADF)
Group A scanned
(Group priority
operation)
(6)
A/D conversion A1
Waiting for conversion
(3)
Waiting for conversion
Waiting for conversion
Stored
A/D conversion A1
(4)
A/D conversion result B2
(5)
Page 861 of 1041

Advertisement

Table of Contents
loading

Table of Contents