Renesas RX100 Series User Manual page 526

32-bit mcu
Hide thumbs Also See for RX100 Series:
Table of Contents

Advertisement

RX13T Group
(29) Operation When Error Occurs in Reset-Synchronized PWM Mode and Operation is Restarted
in Reset-Synchronized PWM Mode
Figure 19.171 shows a case in which an error occurs in reset-synchronized PWM mode and operation is restarted in
reset-synchronized PWM mode after re-setting.
MTU module output
MTIOC3A
MTIOC3B
MTIOC3D
PORT output
Pxx
Pxx
Pxx
Figure 19.171
Error Occurrence in Reset-Synchronized PWM Mode, Recovery in Reset-Synchronized PWM
Mode
(1) to (10) are the same as in Figure 19.168 .
(11) Set MTU output using the MPC and port mode registers (PMR) corresponding to the I/O ports.
(12) Restart operation by setting the TSTRA register.
(13) The reset-synchronized PWM waveform is output on compare match occurrence.
R01UH0822EJ0100 Rev.1.00
Jul 31, 2019
(1)
(2)
(3)
(4)
(5)
TSTR
Reset
TOCR
TMDR
TOER
MPC
(RPWM)
(1)
(MTU)
Hi-Z
Hi-Z
Hi-Z
19. Multi-Function Timer Pulse Unit 3 (MTU3c)
(6)
(7)
(8)
(9)
(10)
(11)
Match
Error
Port
TSTR
MPC
(1)
occurs
output
(0)
(MTU)
(12)
(13)
TSTR
Match
(1)
Page 526 of 1041