RX13T Group
19.4

Interrupt Sources

19.4.1

Interrupt Sources and Priorities

There are three kinds of interrupt source; TGR input capture/compare match, TCNT overflow, and TCNT underflow.
Each interrupt source has its own enable/disable bit, allowing the generation of interrupt request signals to be enabled or
disabled individually.
When an interrupt source is generated, if the corresponding enable/disable bit in TIER is set to 1, an interrupt is
requested.
Relative channel priorities can be changed by the interrupt controller; however the priority within a channel is fixed. For
details, refer to section 14, Interrupt Controller (ICUb) . Table 19.62 lists the MTU interrupt sources.
Table 19.62
MTU Interrupt Sources
Channel
Name
MTU0
TGIA0
TGIB0
TGIC0
TGID0
TCIV0
TGIE0
TGIF0
MTU1
TGIA1
TGIB1
TCIV1
TCIU1
MTU2
TGIA2
TGIB2
TCIV2
TCIU2
MTU3
TGIA3
TGIB3
TGIC3
TGID3
TCIV3
MTU4
TGIA4
TGIB4
TGIC4
TGID4
TCIV4
MTU5
TGIU5
TGIV5
TGIW5
Note:
This table shows the initial state immediately after a reset. The relative channel priorities can be changed by the interrupt
controller.
Note 1. Underflow is available only in complementary PWM mode.
R01UH0822EJ0100 Rev.1.00
Jul 31, 2019
Interrupt Source
MTU0.TGRA input capture/compare match
MTU0.TGRB input capture/compare match
MTU0.TGRC input capture/compare match
MTU0.TGRD input capture/compare match
MTU0.TCNT overflow
MTU0.TGRE compare match
MTU0.TGRF compare match
MTU1.TGRA input capture/compare match
MTU1.TGRB input capture/compare match
MTU1.TCNT overflow
MTU1.TCNT underflow
MTU2.TGRA input capture/compare match
MTU2.TGRB input capture/compare match
MTU2.TCNT overflow
MTU2.TCNT underflow
MTU3.TGRA input capture/compare match
MTU3.TGRB input capture/compare match
MTU3.TGRC input capture/compare match
MTU3.TGRD input capture/compare match
MTU3.TCNT overflow
MTU4.TGRA input capture/compare match
MTU4.TGRB input capture/compare match
MTU4.TGRC input capture/compare match
MTU4.TGRD input capture/compare match
MTU4.TCNT overflow/underflow*
MTU5.TGRU input capture/compare match
MTU5.TGRV input capture/compare match
MTU5.TGRW input capture/compare match
19. Multi-Function Timer Pulse Unit 3 (MTU3c)
1
DTC Activation
Possible
Possible
Possible
Possible
Not possible
Not possible
Not possible
Possible
Possible
Not possible
Not possible
Possible
Possible
Not possible
Not possible
Possible
Possible
Possible
Possible
Not possible
Possible
Possible
Possible
Possible
Possible
Possible
Possible
Possible
Page 470 of 1041
Priority
High
Low