Renesas RX100 Series User Manual page 407

32-bit mcu
Hide thumbs Also See for RX100 Series:
Table of Contents

Advertisement

RX13T Group
Figure 19.28 shows examples of PWM waveform output with 0% duty and 100% duty in PWM mode 1.
In this example, TGRA compare match is set as the TCNT clearing source, a low level is set as the initial output value
and output value for TGRA, and a high level is set as the output value for TGRB.
(1) Example of operation to output the PWM waveform with 0% duty cycle.
TCNT value
TGRB modified
TGRA
TGRB
0000h
MTIOCnA
(2) Example of operation to output the PWM waveform with 100% duty cycle.
TCNT value
TGRB modified
TGRA
TGRB
0000h
MTIOCnA
(3) Example of operation to output the PWM waveform with 0% duty cycle after the output with 100% duty cycle.
TCNT value
TGRB modified
TGRA
TGRB
0000h
MTIOCnA
Figure 19.28
Examples of PWM Mode Operation (PWM Waveform Output with 0% Duty and 100% Duty)
(n = 0 to 4)
R01UH0822EJ0100 Rev.1.00
Jul 31, 2019
TGRB modified
0% duty
Output does not change when compare
matches occur simultaneously in period
register and duty register
TGRB modified
TGRB modified
100% duty
Output does not change when compare
matches occur simultaneously in period
register and duty register
TGRB modified
100% duty
19. Multi-Function Timer Pulse Unit 3 (MTU3c)
TGRB modified
Time
Because there is no signal
change, waveform does not
change even if 1 is output when
second TGRB compare match
occurs
Time
TGRB modified
Time
0% duty
Page 407 of 1041

Advertisement

Table of Contents
loading

Table of Contents