RX13T Group
(24) Operation When Error Occurs in Complementary PWM Mode and Operation is Restarted in
Complementary PWM Mode with New Settings
Figure 19.166 shows a case in which an error occurs in complementary PWM mode and operation is restarted in
complementary PWM mode after re-setting (operation is restarted using new period and duty ratio settings).
Reset
MTU module output
MTIOC3A
MTIOC3B
MTIOC3D
PORT output
Pxx
Pxx
Pxx
Figure 19.166
Error Occurrence in Complementary PWM Mode, Recovery in Complementary PWM Mode (2)
(1) to (10) are the same as in Figure 19.163 .
(11) Set normal mode and make new settings (MTU output goes low).
(12) Disable output in MTU3 and MTU4 with the TOERA register.
(13) Select the complementary PWM output level and enable or disable cyclic output with registers TOCR1A and
TOCR2A.
(14) Set complementary PWM mode.
(15) Enable output in MTU3 and MTU4 with the TOERA register.
(16) Set MTU output using the MPC and port mode registers (PMR) corresponding to the I/O ports.
(17) Restart operation by setting the TSTRA register.
R01UH0822EJ0100 Rev.1.00
Jul 31, 2019
(5)
(1)
(2)
(3)
(4)
(6)
TOCR
TMDR
TOER
MPC
TSTR
(MTU)
(CPWM)
(1)
(1)
Hi-Z
Hi-Z
Hi-Z
19. Multi-Function Timer Pulse Unit 3 (MTU3c)
(7)
(8)
(9)
(10)
(11)
Match
Error
Port
TSTR
TMDR
occurs
output
(0)
(normal)
(16)
(12)
(13)
(14)
(15)
TOER
TOCR
TMDR
TOER
MPC
(MTU)
(0)
(CPWM)
(1)
Page 521 of 1041
(17)
TSTR
(1)

Advertisement

Table of Contents
loading

Table of Contents