RX13T Group
19.5.2
Interrupt Signal Timing
(1) TGI Interrupt Timing by Compare Match
Figure 19.116 and Figure 19.117 show the TGI interrupt request signal timing when a compare match occurs.
TCNT count clock
Compare match signal
Interrupt signal
Figure 19.116
TGI Interrupt Timing (Compare Match) (MTU0 to MTU4)
TCNT count clock
Compare match signal
Interrupt signal
Figure 19.117
TGI Interrupt Timing (Compare Match) (MTU5)
R01UH0822EJ0100 Rev.1.00
Jul 31, 2019
PCLKB
TCNT
N
TGR
N
PCLKB
–
TCNT
N
TGR
19. Multi-Function Timer Pulse Unit 3 (MTU3c)
N + 1
1
N
N
Page 480 of 1041