RX13T Group
(22) Operation When Error Occurs in Complementary PWM Mode and Operation is Restarted in
PWM Mode 1
Figure 19.164 shows a case in which an error occurs in complementary PWM mode and operation is restarted in PWM
mode 1 after re-setting.
MTU module output
MTIOC3A
MTIOC3B
MTIOC3D
PORT output
Pxx
Pxx
Pxx
Figure 19.164
Error Occurrence in Complementary PWM Mode, Recovery in PWM Mode 1
(1) to (10) are the same as in Figure 19.163 .
(11) Set PWM mode 1 (MTU output goes low).
(12) Initialize the pins with the TIOR register. (In PWM mode 1, waveforms are not output to the MTIOCnB
(MTIOCnD) pins. To output a specified level, make necessary settings for general output ports in the port direction
registers (PDR) and port output data registers (PODR) of the I/O ports.)
(13) Set MTU output using the MPC and port mode registers (PMR) corresponding to the I/O ports.
(14) Restart operation by setting the TSTRA register.
R01UH0822EJ0100 Rev.1.00
Jul 31, 2019
(1)
(2)
(3)
(4)
(5)
Reset
TOCR
TMDR
TOER
MPC
TSTR
(CPWM)
(1)
(MTU)
Hi-Z
Hi-Z
Hi-Z
19. Multi-Function Timer Pulse Unit 3 (MTU3c)
(6)
(7)
(8)
(9)
(10)
(11)
Match
Error
Port
TSTR
TMDR
(1)
occurs
output
(0)
(PWM1)
(13)
(12)
(14)
TIOR
MPC
TSTR
(MTU)
(1 init
(1)
0 out)
Not initialized (MTIOC3B)
Not initialized (MTIOC3D)
Page 519 of 1041

Advertisement

Table of Contents
loading

Table of Contents