Renesas RX100 Series User Manual page 520

32-bit mcu
Hide thumbs Also See for RX100 Series:
Table of Contents

Advertisement

RX13T Group
(23) Operation When Error Occurs in Complementary PWM Mode and Operation is Restarted in
Complementary PWM Mode
Figure 19.165 shows a case in which an error occurs in complementary PWM mode and operation is restarted in
complementary PWM mode after re-setting (when operation is restarted using the period and duty settings at the time of
stopping the counter).
MTU module output
MTIOC3A
MTIOC3B
MTIOC3D
PORT output
Pxx
Pxx
Pxx
Figure 19.165
Error Occurrence in Complementary PWM Mode, Recovery in Complementary PWM Mode (1)
(1) to (10) are the same as in Figure 19.163 .
(11) Set MTU output using the MPC and port mode registers (PMR) corresponding to the I/O ports.
(12) Restart operation by setting the TSTRA register.
(13) The complementary PWM waveform is output on compare match occurrence.
R01UH0822EJ0100 Rev.1.00
Jul 31, 2019
(1)
(2)
(3)
(4)
(5)
Reset
TOCR
TMDR
TOER
MPC
TSTR
(CPWM)
(1)
(MTU)
Hi-Z
Hi-Z
Hi-Z
19. Multi-Function Timer Pulse Unit 3 (MTU3c)
(6)
(7)
(8)
(9)
(10)
(11)
Match
Error
Port
TSTR
MPC
(1)
occurs
output
(0)
(MTU)
(12)
(13)
TSTR
Match
(1)