Timer Synchronous Register (Tsyra) - Renesas RX100 Series User Manual

32-bit mcu
Hide thumbs Also See for RX100 Series:
Table of Contents

Advertisement

RX13T Group
19.2.17

Timer Synchronous Register (TSYRA)

Address(es): MTU.TSYRA 0009 5281h
b7
b6
SYNC4 SYNC3
Value after reset:
0
0
Bit
Symbol
Bit Name
b0
SYNC0
Timer Synchronous
Operation 0
b1
SYNC1
Timer Synchronous
Operation 1
b2
SYNC2
Timer Synchronous
Operation 2
b5 to b3
Reserved
b6
SYNC3
Timer Synchronous
Operation 3
b7
SYNC4
Timer Synchronous
Operation 4
TSYRA selects independent operation or synchronous operation of TCNT in MTU0 to MTU4.
A channel performs synchronous operation when the corresponding bit in TSYR is set to 1.
SYNCn Bits (Timer Synchronous Operation n) (n = 0, 1, 2, 3, 4)
Each bit selects whether operation is independent of or synchronized with other channels.
When synchronous operation is selected, the TCNT synchronous setting of multiple channels and synchronous clearing
by counter clearing on another channel are possible.
To set synchronous operation, the SYNC bits for at least two channels must be set to 1. To set synchronous clearing, in
addition to the SYNC bit, the TCNT clearing source must also be set by means of the TCR.CCLR[2:0] bits.
R01UH0822EJ0100 Rev.1.00
Jul 31, 2019
b5
b4
b3
b2
SYNC2 SYNC1 SYNC0
0
0
0
0
Description
0: MTU0.TCNT operates independently (TCNT setting/clearing is not
related to other channels).
1: MTU0.TCNT performs synchronous operation.
(TCNT synchronous setting/synchronous clearing is enabled.)
0: MTU1.TCNT operates independently (TCNT setting/clearing is not
related to other channels).
1: MTU1.TCNT performs synchronous operation.
(TCNT synchronous setting/synchronous clearing is enabled.)
0: MTU2.TCNT operates independently (TCNT setting/clearing is not
related to other channels).
1: MTU2.TCNT performs synchronous operation.
(TCNT synchronous setting/synchronous clearing is enabled.)
These bits are read as 0. The write value should be 0.
0: MTU3.TCNT operates independently (TCNT setting/clearing is not
related to other channels).
1: MTU3.TCNT performs synchronous operation.
(TCNT synchronous setting/synchronous clearing is enabled.)
0: MTU4.TCNT operates independently (TCNT setting/clearing is not
related to other channels).
1: MTU4.TCNT performs synchronous operation.
(TCNT synchronous setting/synchronous clearing is enabled.)
19. Multi-Function Timer Pulse Unit 3 (MTU3c)
b1
b0
0
0
R/W
R/W
R/W
R/W
R/W
R/W
R/W
Page 359 of 1041