Voltage Monitoring 1 Circuit Status Register (Lvd1Sr) - Renesas RX100 Series User Manual

32-bit mcu
Hide thumbs Also See for RX100 Series:
Table of Contents

Advertisement

RX13T Group
8.2.2

Voltage Monitoring 1 Circuit Status Register (LVD1SR)

Address(es): 0008 00E1h
b7
b6
0
0
Value after reset:
Bit
Symbol
Bit Name
b0
LVD1DET
Voltage Monitoring 1 Voltage Change
Detection Flag
b1
LVD1MON
Voltage Monitoring 1 Signal Monitor Flag
b7 to b2
Reserved
Note:
Set the PRCR.PRC3 bit to 1 (write enabled) before rewriting this register.
Note 1. Only 0 can be written to this bit. After writing 0 to this bit, it takes two system clock cycles for the bit to be read as 0.
LVD1DET Flag (Voltage Monitoring 1 Voltage Change Detection Flag)
The LVD1DET flag is enabled when the LVCMPCR.LVD1E bit is 1 (voltage detection 1 circuit enabled) and the
LVD1CR0.LVD1CMPE bit is 1 (voltage monitoring 1 circuit comparison result output enabled).
The LVD1DET flag should be set to 0 after LVD1CR0.LVD1RIE is set to 0 (disabled). LVD1CR0.LVD1RIE can be set
to 1 (enabled) again after a period of two or more cycles of PCLKB has elapsed.
With read access to an I/O register which access cycle number is defined by PCLKB, two or more cycles of PCLKB may
have to be secured as waiting time.
LVD1MON Flag (Voltage Monitoring 1 Signal Monitor Flag)
The LVD1MON flag is enabled when the LVCMPCR.LVD1E bit is 1 (voltage detection 1 circuit enabled) and the
LVD1CR0.LVD1CMPE bit is 1 (voltage monitoring 1 circuit comparison result output enabled).
R01UH0822EJ0100 Rev.1.00
Jul 31, 2019
b5
b4
b3
b2
LVD1M
0
0
0
0
b1
b0
LVD1D
ON
ET
1
0
Description
0: Not detected
1: Vdet1 passage detection
0: VCC < Vdet1
1: VCC ≥ Vdet1 or LVD1MON circuit is disabled
These bits are read as 0. The write value should be 0.
8. Voltage Detection Circuit (LVDAb)
Page 116 of 1041
R/W
R/(W)
1
*
R
R/W