The hard processor system (HPS) provides two controller area network (CAN) controllers for serial
communication with the Cortex-A9 microprocessor unit (MPU) subsystem host processor and the direct
memory access (DMA) controller using the CAN protocol. The CAN controllers are instances of the Bosch
D_CAN controller and compliant with ISO 11898-1.

Features of the CAN Controller

The CAN controllers offer the following features:
• Compliant with CAN Protocol Specification 2.0 parts A and B, available from the Bosch website.
• Programmable communication rate up to 1 Mbps
• Holds up to 128 messages
• Error correction code (ECC)
• 11-bit standard and 29-bit extended identifiers
• Programmable loopback mode
• External direct memory access (DMA) controller for large data transfers
• Automatic retransmission
Related Information
Bosch Website
2013 Altera Corporation. All rights reserved. ALTERA, ARRIA, CYCLONE, HARDCOPY, MAX, MEGACORE, NIOS, QUARTUS and STRATIX words
and logos are trademarks of Altera Corporation and registered in the U.S. Patent and Trademark Office and in other countries. All other
words and logos identified as trademarks or service marks are the property of their respective holders as described at
www.altera.com/common/legal.html. Altera warrants performance of its semiconductor products to current specifications in accordance with
Altera's standard warranty, but reserves the right to make changes to any products and services at any time without notice. Altera assumes
no responsibility or liability arising out of the application or use of any information, product, or service described herein except as expressly
agreed to in writing by Altera. Altera customers are advised to obtain the latest version of device specifications before relying on any published
information and before placing orders for products or services.
www.altera.com
101 Innovation Drive, San Jose, CA 95134

CAN Controller Introduction

Send Feedback
25
®
ISO
9001:2008
Registered

Advertisement

Table of Contents
loading

Table of Contents