RX13T Group
Note 1. Supply current values do not include output charge/discharge current from all pins. The values apply when internal pull-up
resistors are disabled.
Note 2. Peripheral module clocks are stopped. This does not include BGO operation. The clock source is the PLL. FCLK and PCLK are
set for division by 64.
Note 3. Peripheral module clocks are supplied. This does not include BGO operation. The clock source is the PLL. The FCLK and PCLK
operating clocks run at the same frequency as ICLK.
Note 4. Values when VCC = 5 V.
Note 5. This is an increase caused by program/erase operation to the ROM or E2 DataFlash during executing the user program.
Note 6. Peripheral module clocks are stopped. The clock source is the PLL when ICLK is 12 MHz, is the HOCO when the ICLK is at 8
MHz, or is the LOCO when the ICLK is at another frequency. FCLK and PCLK are set for division by 64.
Note 7. Peripheral module clocks are supplied. The clock source is the PLL when ICLK is 12 MHz, is the HOCO when the ICLK is at 8
MHz, or is the LOCO when the ICLK is at another frequency. The FCLK and PCLK operating clocks run at the same frequency
as ICLK.
Table 32.7
DC Characteristics (4)
Conditions: VCC = 2.7 V to 5.5 V, AVCC0 = VCC to 5.5 V, VSS = AVSS0 = 0 V, T
Item
Supply
Software standby
1
2
current*
mode*
Note 1. Supply current values are with all output pins unloaded and all input pull-up resistors are disabled.
Note 2. The IWDT and LVD are stopped.
Note 3. VCC = 5 V.
R01UH0822EJ0100 Rev.1.00
Jul 31, 2019
Symbol
Typ.*
T
= 25°C
I
0.44
a
CC
T
= 55°C
0.60
a
T
= 85°C
1.16
a
T
= 105°C
2.38
a
= –40 to +105°C
a
3
Max.
Unit
0.74
μA
1.78
8.36
20.49
32. Electrical Characteristics
Test Conditions