ADTRAN AOS Version R10.1.0 Command Reference Manual page 491

Adtran operating system (aos)
Table of Contents

Advertisement

Command Reference Guide
show ethernet cfm mep remote
Use the show ethernet cfm mep remote command to display configuration and statistical information for
all remote Ethernet operations, administration, and maintenance (OAM) connectivity fault management
(CFM) maintenance endpoints (MEPs) stored on the system. Variations of this command include:
show ethernet cfm mep remote
show ethernet cfm mep remote domain <domain name> association <association name>
show ethernet cfm mep remote domain none association <association name>
show ethernet cfm mep remote interface <interface>
show ethernet cfm mep remote level <level>
show ethernet cfm mep remote local-mep <mep id>
show ethernet cfm mep remote remote-mep <mep id>
The output of all show commands can be limited by appending the following modifiers to
the end of the command: | begin <text>, | exclude <text>, and | include <text>. The
include modifier limits output to lines that contain the specified text, the exclude modifier
excludes any lines with the specified text, and the begin modifier displays the first line of
output with the specified text and all lines thereafter.
For specific instructions and examples regarding these modifiers, refer to the introduction
of the
Enable Mode Command Set on page
Syntax Description
domain <domain name>
none
association <association name>
interface <interface>
level <level>
local-mep <mep id>
remote-mep <mep id>
Default Values
By default, all remote MEPs for all local MEPs are displayed.
By default, MEPs in all levels are displayed.
60000CRG0-35E
83.
Optional. Specifies that output is limited to MEPs in the specified
domain.
Optional. Specifies no domain name is used.
Optional. Specifies that output is limited to MEPs in the specified
association.
Optional. Specifies that output is limited to the MEPs configured on
the specified interface. Specify an interface in the format <interface
type [slot/port | slot/port.subinterface id | interface id |
interface id. subinterface id]>. For example, for an Ethernet
subinterface, use eth 0/1.1. For a list of appropriate interfaces, enter
interface ? at the prompt.
Optional. Specifies that output is limited to MEPs in the specified
maintenance level. Levels range from 0 to 7.
Optional. Specifies that output is limited to the remote MEPs for all
local MEPs with the specified ID. MEP ID range is 1 to 8191.
Optional. Specifies that output is limited to the remote MEPs with the
specified ID. MEP ID range is 1 to 8191.
Copyright © 2012 ADTRAN, Inc.
Enable Mode Command Set
491

Hide quick links:

Advertisement

Table of Contents
loading

Related Products for ADTRAN AOS Version R10.1.0

This manual is also suitable for:

Aos r10.1.0

Table of Contents