ADTRAN AOS Version R10.1.0 Command Reference Manual page 250

Adtran operating system (aos)
Table of Contents

Advertisement

Command Reference Guide
debug ethernet cfm alarm
Use the debug ethernet cfm alarm command to activate debug messages associated with Ethernet
operations, administration, and maintenance (OAM) connectivity fault management (CFM) fault alarms.
Debug messages are displayed (real time) on the terminal (or Telnet) screen. Use the no form of this
command to disable the debug messages. Variations of this command include:
debug ethernet cfm alarm
debug ethernet cfm alarm domain <domain name>
debug ethernet cfm alarm domain <domain name> association <association name>
debug ethernet cfm alarm domain <domain name> association <association name> mep <mep id>
Turning on a large amount of debug information can adversely affect the performance of
your unit.
Syntax Description
domain <domain name>
association <association name> Optional. Specifies that debug output is limited to alarm information for
mep <mep id>
Default Values
By default, all debug messages in AOS are disabled.
Command History
Release 17.4
Functional Notes
For more information regarding Ethernet OAM CFM and its operation on AOS products, refer to the
Ethernet OAM CFM in AOS configuration guide available online at
(article number 3013).
60000CRG0-35E
Optional. Specifies that debug output is limited to alarm information for
maintenance endpoints (MEPs) of a specific domain.
MEPs of a specific association.
Optional. Specifies that debug output is limited to alarm information for
MEPs that match a specific MEP ID. MEP ID range is 1 to 8191.
Command was introduced.
Copyright © 2012 ADTRAN, Inc.
Enable Mode Command Set
https://supportforums.adtran.com