ping ethernet
Use the ping ethernet command to initiate a loopback message from one Ethernet operations,
administration, and maintenance (OAM) connectivity fault management (CFM) maintenance endpoint
(MEP) to another MEP. These loopback messages are used to test the accessibility of the destination MEP.
Variations of this command include:
ping ethernet <target-mac-address | target-mep-id>
ping ethernet <target-mac-address | target-mep-id> count <number>
ping ethernet <target-mac-address | target-mep-id> data <pattern>
ping ethernet <target-mac-address | target-mep-id> domain <domain name> association <association
name>
ping ethernet <target-mac-address | target-mep-id> domain none association <association name>
ping ethernet <target-mac-address | target-mep-id> drop-eligible
ping ethernet <target-mac-address | target-mep-idl> interface <interface>
ping ethernet <target-mac-address | target-mep-id> mep <mep id>
ping ethernet <target-mac-address | target-mep-id> priority <priority>
ping ethernet <target-mac-address | target-mep-id> repeat <number>
ping ethernet <target-mac-address | target-mep-id> size <bytes>
ping ethernet <target-mac-address | target-mep-id> timeout <timeout>
ping ethernet <target-mac-address | target-mep-id> validate-data
ping ethernet <target-mac-address | target-mep-id> verbose
ping ethernet <target-mac-address | target-mep-id> wait <interval>
After specifying the target for the loopback messages, the other parameters can be entered
in any order.
Syntax Description
<target-mac-address | target-mep-id>
count <number>
data <pattern>
domain <domain name>
domain none
association <association name>
60000CRG0-35E
Specifies the destination for the loopback message. Medium
access control (MAC) addresses are entered in the format
HH:HH:HH:HH:HH:HH. Target MEP IDs are the unique
numerical values identifying MEPs. MEP IDs range from 1 to
8191.
Optional. Specifies the number of loopback messages to send.
Range is 1 to 1000000.
Optional. Specifies the pattern to be carried in the data time
length value (TLV) of the loopback message. Pattern is up to four
hexadecimal digits. Pattern range is 0 to ffff.
Optional. Specifies the maintenance domain to which the
transmitting MEP belongs.
Optional. Specifies no maintenance domain.
Optional. Specifies the maintenance association to which the
transmitting MEP belongs.