show ethernet cfm mep local
Use the show ethernet cfm mep local command to display configuration and statistical information for all
Ethernet operations, administration, and maintenance (OAM) connectivity fault management (CFM)
maintenance endpoints (MEPs) configured on the system. Variations of this command include:
show ethernet cfm mep local
show ethernet cfm mep local detail
show ethernet cfm mep local domain <domain name> association <association name>
show ethernet cfm mep local fault
show ethernet cfm mep local interface <interface>
show ethernet cfm mep local mep-id <mep id>
show ethernet cfm mep local statistics
The output of all show commands can be limited by appending the following modifiers to
the end of the command: | begin <text>, | exclude <text>, and | include <text>. The
include modifier limits output to lines that contain the specified text, the exclude modifier
excludes any lines with the specified text, and the begin modifier displays the first line of
output with the specified text and all lines thereafter.
For specific instructions and examples regarding these modifiers, refer to the introduction
of the
Enable Mode Command Set on page
Syntax Description
detail
domain <domain name>
association <association name> Optional. Specifies that output is limited to MEPs in the specified
fault
interface <interface>
mep-id <mep id>
statistics
Default Values
No default values are necessary for this command.
60000CRG0-35E
Optional. Specifies the format is in detail, rather than summary, format.
Optional. Specifies that output is limited to MEPs in the specified
domain.
association.
Optional. Specifies that output is limited to only MEP fault information.
Optional. Specifies that output is limited to the MEPs configured on the
specified interface. Specify an interface in the format <interface type
[slot/port | slot/port.subinterface id | interface id |
interface id. subinterface id]>. For example, for an Ethernet
subinterface, use eth 0/1.1. For a list of appropriate interface, enter
interface ? at the prompt.
Optional. Specifies that output is limited to MEPs with the specified ID.
MEP ID range is 1 to 8191.
Optional. Specifies that only MEP statistics are displayed.