No Loopd Reaction Remote - Siemens SCALANCE XM-400 Configuration Manual

Simatic net industrial ethernet switches command line interface (cli)
Hide thumbs Also See for SCALANCE XM-400:
Table of Contents

Advertisement

Syntax
Call the command without parameters:
loopd reaction remote
Result
"disable" is activated for the
"disable" is the default after enabling loop detection.
Further notes
You enable the "no action" reaction with the
You can display the status of this function and other information with the
command.
12.3.3.7

no loopd reaction remote

Description
With this command, you enable the "no action" reaction for a remote loop. If a remote loop is
detected, this has no effect on the port.
Requirement
● loopd is enabled
● You are in the Interface configuration mode.
The command prompt is:
cli(config-if-$$$)#
Syntax
Call the command without parameters:
no loopd reaction remote
Result
"no action" is activated for the
"disable" is the default after enabling loop detection.
Further notes
You enable the "disable" setting with the
You can display the status of this function and other information with the
command.
SCALANCE XM-400/XR-500 Command Line Interface (CLI)
Configuration Manual, 06/2016, C79000-G8976-C252-11
loopd reaction remote
no loopd reaction remote
loop reaction remote
loopd reaction remote
12.3 Loop detection
function.
command.
show loopd
function.
command.
show loopd
Diagnostics
921