7.5.3.3

Option (IP address)

Description
With this command you configure the DHCP options 3 and 6 that contain an IPv4 address as
DHCP parameter. The DHCP options 3 and 6 are created automatically when the IPv4
address band is created.
Requirement
You are in the DHCPPOOL configuration mode.
The command prompt is as follows:
cli(config-dhcp-pool-<ID>)#
Syntax
Call up the command with the following parameters:
option <option-code> { <ip-address-list> | int-ip }
The parameters have the following meaning:
Parameter
option-code
ip-adress-
list
int-ip
Result
The DHCP option is created.
Further notes
You display the setting with the
You disable the IPv4 address band with the
You delete the DHCP option with the
SCALANCE XM-400/XR-500 Command Line Interface (CLI)
Configuration Manual, 06/2016, C79000-G8976-C252-11
Description
Code of the DHCP option
IPv4 address or IPv4 address list
Uses IPv4 address of the interface that is
assigned to the IPv4 address band.
show ip dhcp-server pools
no option
Range of values / note
3 - Default gateway
6 - DNS server
DHCP option 3 (default gateway):
Enter the DHCP parameter as an
IPv4 address, e.g. 192.168.100.2.
DHCP option 6 (name server):
Enter the DHCP parameter as an
IPv4 address, e.g. 192.168.100.2.
You can specify up to three IPv4 ad-
dresses separated by commas.
Only with DHCP option 3
command.
command.
no pool-enable
command.
Network protocols
7.5 DHCP server