4.2.2

Commands in the global configuration mode

This section describes commands that you can call up in the Global configuration mode.
In Privileged EXEC mode, enter the
Commands relating to other topics that can be called in the Global configuration mode can
be found in the relevant sections.
You exit the Global configuration mode with the
Privileged EXEC mode again.
4.2.2.1

web-session-timeout

Description
With this command, you enable the automatic logoff and you configure the timeout setting for
the WBM.
Requirement
You are in the Global configuration mode.
The command prompt is as follows:
cli(config)#
Syntax
Call up the command with the following parameters:
web-session-timeout[seconds(60-3600)]
The parameter has the following meaning:
Parameter
seconds
Result
The time is configured and automatic logout is enabled.
Further notes
You disable automatic logoff with the
You display the current timeout setting with the
SCALANCE XM-400/XR-500 Command Line Interface (CLI)
Configuration Manual, 06/2016, C79000-G8976-C252-11
configure terminal
Description
Time in seconds until automatic logout
after the last entry
no web-session-timeout
Functions specific to SCALANCE
command to change to this mode.
or
command and are then in the
end
exit
Range of values / note
60 ... 3600
Default: 900
command.
show web-session-timeout