Layer 3 functions
9.2 OSPFv2 (IPv4)
[{
}]
The parameters have the following meaning:
Parameter
area-id
router-id
authentication
hello-interval
value
retransmit-interval
value
transmit-delay
value
dead-interval
value
authentication-key
key
message-digest-key
key-id
532
authentication-key <key (8)> | message-digest-key <Key-id (0-255)>
md5 <key(16)>
Description
Area-ID
ID of the router. The router ID must
correspond to the IP address of the
interface of the transit area network.
Keyword for the authentication method
of the virtual connection
Keyword for the interval at which Hello
packets are sent over the virtual link
specifies the length of the interval in
seconds.
Keyword for the interval after which
packets whose receipt was not con-
firmed are transferred again.
specifies the length of the interval in
seconds.
Keyword for the time that a link state
update packet requires for transmis-
sion over the virtual link.
Specifies the length of the interval in
seconds.
Keyword for the interval after which the
neighbor router is classified as "failed"
if Hello packets from it are not re-
ceived.
Specifies the length of the interval in
seconds.
Keyword for the unencrypted password -
Password
Keyword for the ID of the password
ID of the password.
Range of values / note
specify a valid ID.
x.x.x.x
x = 0 ... 255
0.0.0.0 = backbone area
-
simple
enables authentication using a
password
messagedigest
enables authentication using
MD5
none
no authentication
-
enter the interval
1-65535
-
enter the interval
0-3600
-
enter the interval
0-3600
-
enter the interval
0–0x7fffffff
enter the password.
Maximum length:
-
specify the ID
0 ... 255
SCALANCE XM-400/XR-500 Command Line Interface (CLI)
Configuration Manual, 06/2016, C79000-G8976-C252-11
characters
8