Load control
10.1 Rate control
For information on names of addresses and interfaces, refer to the section "Interface
identifiers and addresses (Page 42)".
If you do not select any parameter from the parameter list, the entries are displayed for all
available interfaces.
Result
The entries are displayed.
10.1.2

Commands in the interface configuration mode

This section describes commands that you can call up in the interface configuration mode.
Depending on the Interface selected, various command sets are available.
In the Global configuration mode, enter the
Commands relating to other topics that can be called in the interface configuration mode can
be found in the relevant sections.
● If you exit the Interface configuration mode with the
Global configuration mode.
● If you exit the Interface configuration mode with the
Privileged EXEC mode.
10.1.2.1

rate-limit output

Description
With this command, you configure and enable the data rate in Kbps for limiting the outgoing
data stream of the interface.
Requirement
You are in the Interface configuration mode.
The command prompt is as follows:
cli(config-if-$$$)#
Syntax
Call up the command with the following parameters:
rate-limit output <rate-value>