No Standby Port - Siemens SCALANCE XM-400 Configuration Manual

Simatic net industrial ethernet switches command line interface (cli)
Hide thumbs Also See for SCALANCE XM-400:
Table of Contents

Advertisement

Requirement
You are in the Redundancy configuration mode.
The command prompt is as follows:
cli(config-red)#
Syntax
Call up the command with the following parameters:
standby port {<interface-type> <interface-id>}
The parameters have the following meaning:
Parameter
interface-type
interface-id
For information on names of addresses and interfaces, refer to the section "Interface
identifiers and addresses (Page 42)".
Result
The ports for a standby connection are configured and enabled.
Further notes
You disable the setting with the
You can display the status of this function and other information with the
redundancy
8.5.6.7

no standby port

Description
With this command, disable the port for a standby connection on a device.
Requirement
You are in the Redundancy configuration mode.
The command prompt is as follows:
cli(config-red)#
Syntax
Call up the command with the following parameters:
no standby port [<interface-type><interface-id>}
SCALANCE XM-400/XR-500 Command Line Interface (CLI)
Configuration Manual, 06/2016, C79000-G8976-C252-11
Description
Type or speed of the interface
Module no. and port no. of the interface
no standby port
command.
Layer 2 management protocols
8.5 Ring redundancy and standby connection
Range of values / note
Enter a valid interface.
command.
show ring-
483