Ptp Transparent-Clock Configuration - Siemens SCALANCE XM-400 Configuration Manual

Simatic net industrial ethernet switches command line interface (cli)
Hide thumbs Also See for SCALANCE XM-400:
Table of Contents

Advertisement

Syntax
Call up the command with the following parameters:
ptp time diff <(+/-hh:mm)>
The parameter has the following meaning:
Parameter
+/-hh:mm
Result
The time zone for the Precision Time Protocol is specified.
5.4.2.4

ptp transparent-clock configuration

Description
With this command you change to the PT Transparent Clock configuration mode.
Requirement
You are in the Global configuration mode.
The command prompt is as follows:
cli(config)#
Syntax
Call the command without parameter assignment:
ptp transparent-clock configuration
Result
You are in the PTP Transparent Clock configuration mode.
The command prompt is as follows:
cli(config-ptp-tc)#
SCALANCE XM-400/XR-500 Command Line Interface (CLI)
Configuration Manual, 06/2016, C79000-G8976-C252-11
Description
The value for the time difference.
System time
5.4 PTP Client
Range of values / note
Hours and minutes specified in
the format
+/-HH:MM
175

Advertisement

Table of Contents
loading

Table of Contents