9.4.4.13

no vrrp timer

Description
With this command, you reset the time interval to the default value.
Note
This command is available only with layer 3.
Requirement
● Routing with VRRP is enabled.
● An IPv4 address is assigned to the virtual router.
● You are in the VRRP Interface configuration mode
.The command prompt is:
cli (config-vrrp-if)#
Syntax
Call up the command with the following parameters:
no vrrp <vrid(1-255)> timer
The parameter has the following meaning:
Parameter
vrid
Result
The time interval is reset.
Further notes
You configure a VRRP interface with the
You enable routing with VRRP with the
You configure the interval with the
You assign IPv4 addresses to a virtual router with the
You show the interval with the
SCALANCE XM-400/XR-500 Command Line Interface (CLI)
Configuration Manual, 06/2016, C79000-G8976-C252-11
Description
ID of the virtual router
interface
router vrrp
command.
vrrp timer
show vrrp interface - vrid
9.4 VRRPv2 (IPv4)
Range of values / note
1 ... 255
command.
command.
command.
vrrp ipv4
command.
Layer 3 functions