Sntp Time Diff - Siemens SCALANCE XM-400 Configuration Manual

Simatic net industrial ethernet switches command line interface (cli)
Hide thumbs Also See for SCALANCE XM-400:
Table of Contents

Advertisement

The parameters have the following meaning:
Parameter
unicast
broadcast
Result
The addressing mode of the SNTP client is configured.
Further notes
You display this setting and other information with the
You display the settings for the unicast mode with the
command.
You display the settings for the broadcast mode with the
command.
5.3.3.2

sntp time diff

Description
With this command, you configure the time difference of the system time relative to the UTC
time.
Requirement
● The SNTP server must have started up.
● You are in the SNTP Configuration mode.
The command prompt is:
cli(config-sntp)#
Syntax
Call up the command with the following parameters:
sntp time diff <(+/-hh:mm)>
The parameter has the following meaning:
Parameter
+
-
SCALANCE XM-400/XR-500 Command Line Interface (CLI)
Configuration Manual, 06/2016, C79000-G8976-C252-11
Description
configures the SNTP client in unicast
mode
configures the SNTP client in broad-
cast mode
Description
Time zones to the west of the SNTP server time zone
Time zones to the east of the SNTP server time zone
5.3 SNTP Client
Range of values / note
Default: unicast enabled
Supports only IPv4 addresses
command.
show sntp status
show sntp unicast-mode status
show sntp broadcast-mode status
System time
169