No Ipv6 Ospf Metric - Siemens SCALANCE XM-400 Configuration Manual

Simatic net industrial ethernet switches command line interface (cli)
Hide thumbs Also See for SCALANCE XM-400:
Table of Contents

Advertisement

Layer 3 functions
9.3 OSPFv3 (IPv6)
The parameter has the following meaning:
Parameter
metric
Result
The metric is specified.
Further notes
You enable OSPFv3 routing with the
You can reset the metric to the default with the
You display the configuration with the
9.3.4.8

no ipv6 ospf metric

Description
With this command, you reset the metric back to the default value.
Note
This command is available only with layer 3.
Requirement
● The interface is an IPv6 interface.
● You are in the Interface configuration mode
The command prompt is as follows:
cli(config-if-$$)#
Syntax
Call the command without parameter assignment:
no ipv6 ospf metric
Result
The metric is reset.
608
Description
Value for the metric
ipv6 router ospf
show ipv6 ospf interface
Range of values / note
1 ... 65535
Default: 1
command.
no ipv6 ospf metric
command.
SCALANCE XM-400/XR-500 Command Line Interface (CLI)
Configuration Manual, 06/2016, C79000-G8976-C252-11
command.