Network protocols
7.8 SNMP
The command prompt is as follows:
cli(config)#
Syntax
Call up the command with the following parameters:
snmp access <GroupName> {v1|v2c|v3 {auth|noauth|priv}}
[read <ReadView|none>][write <WriteView|none>][notify <NotifyView|none>]
[{volatile|nonvolatile}]
The parameters have the following meaning:
Parameter
GroupName
Version
Authentication
read
write
notify
Storage type
The keywords need to be specified.
If optional parameters are not specified when configuring a group, the default value will be
used.
394
Description
Name of the group to which access is
configured
Selects the version of the protocol
used
Selects the authentication method:
the data can be read
Keyword
the data can be read and written
Keyword
Changes can be set as a tag
Keyword
specifies whether the settings remain
following a restart
SCALANCE XM-400/XR-500 Command Line Interface (CLI)
Range of values / note
max. 32 characters
v1
v2c
v3
auth
enables MD5 or SHA as au-
thentication method
noauth
no authentication
priv
enables authentication and
encryption
ReadView
none
WriteView
none
NotifyView
none
volatile
The settings are lost after a
restart
nonvolatile
The settings are retained after
a restart