The parameters have the following meaning:
Parameter
always
metric
metric-value
metric-type
type
Result
The function is enabled.
Further notes
You disable the function with the
9.2.3.14

no default-information originate

Description
With this command, you disable the function with which a standard route is generated for
external routes into the OSPF routing domain.
Note
This command is available only with layer 3.
Requirement
You are in the OSPF Router configuration mode.
The command prompt is as follows:
cli(config-ospf)#
SCALANCE XM-400/XR-500 Command Line Interface (CLI)
Configuration Manual, 06/2016, C79000-G8976-C252-11
Description
An external standard route is always
generated.
Keyword for the metric of the external
standard route.
Value of the metric
Keyword for the type of the external
standard route
Type of the external route
no default-information originate
Layer 3 functions
9.2 OSPFv2 (IPv4)
Range of values / note
--
0-0xffffff
--
1 - type 1
External and internal costs
2 - type 2
External costs
command.