Siemens SCALANCE XM-400 Configuration Manual page 747

Simatic net industrial ethernet switches command line interface (cli)
Hide thumbs Also See for SCALANCE XM-400:
Table of Contents

Advertisement

Syntax
Call up the command with the following parameters:
ip nat service <inside local ip> [<inside local port number>]
{ auth | dns | ftp | pop3 | pptp | smtp | telnet | http | nntp | snmp | other
[<inside global port number>]}
[{ tcp | udp | any }] [<description>]
The parameters have the following meaning:
Parameter
inside local ip
inside local port
number
Service
inside global port
number
Protocol
description
Result
The static port translation with a service is configured.
Further notes
You delete a configuration with the
SCALANCE XM-400/XR-500 Command Line Interface (CLI)
Configuration Manual, 06/2016, C79000-G8976-C252-11
Description
Actual address of the device that
should be reachable from exter-
nal.
Port that will be assigned to the
inside local address.
Service for which the port transla-
tion is valid.
Port that will be assigned to the
inside global address.
Protocol for which the port trans-
lation is valid.
Description for the port translation -
no ip nat service
Layer 3 functions
Range of values / note
Enter a valid IPv4 address.
If you do not specify any ports, the port
that you assign for the
inside global
parameter will be en-
port number
tered.
auth
dns
ftp
pop3
pptp
smtp
telnet
http
nntp
snmp
other
If you have selected the
you can enter a port.
If you have selected another service, a
port will be specified.
tcp
udp
any
command.
9.9 NAT (IPv4)
service,
other
747