Passive-Listening Bpdu-Vlan-Flood; No Passive-Listening Bpdu-Vlan-Flood - Siemens SCALANCE XM-400 Configuration Manual

Simatic net industrial ethernet switches command line interface (cli)
Hide thumbs Also See for SCALANCE XM-400:
Table of Contents

Advertisement

6.4.2.1

passive-listening bpdu-vlan-flood

Description
With this command you enable forwarding of BPDUs for specific VLANs; in other words to all
ports that are members of a VLAN.
Requirement
You are in the Global configuration mode.
The command prompt is as follows:
cli(config)#
Syntax
Call the command without parameters:
passive-listening bpdu-vlan-flood
As default the function is "enabled".
Result
BPDUs for specific VLANs.
Further notes
You disable this function with the
You display the status of "passive listening" with the
6.4.2.2

no passive-listening bpdu-vlan-flood

Description
With this command you enable the flooding of BPDUs to all available ports of the device
regardless of the configured VLANs.
Requirement
You are in the Global configuration mode.
The command prompt is as follows:
cli(config)#
SCALANCE XM-400/XR-500 Command Line Interface (CLI)
Configuration Manual, 06/2016, C79000-G8976-C252-11
no passive-listening bpdu-vlan-flood
show passive-listening
Network structures
6.4 Passive Listening
command.
command.