Diagnostics
12.1 Event and fault handling
Requirement
You are in the User EXEC mode or in the Privileged EXEC mode.
The command prompt is as follows:
cli>
Syntax
Call the command without parameters:
show events severity
Result
The corresponding degree of severity is shown for each type of notification.
Further notes
You configure the assignment of the degree of severity of an event and the type of
notification with the
12.1.3.3

show events faults config

Description
This command shows the current configuration of the following error monitoring functions:
● Monitoring of the power supply for power outage
● Monitoring of the network connections for a change in the connection status
Requirement
You are in the User EXEC mode or in the Privileged EXEC mode.
The command prompt is as follows:
cli>
Syntax
Call up the command with the following parameters:
show events faults config [{power|link}]
The parameters have the following meaning:
Parameter
power
link
If no parameters are specified, the settings for both error monitoring functions are displayed.
886
or
cli#
severity
or
cli#
Description
Monitoring of the power supply for power outage
Monitoring of the network connections for a change in the connection status
command.
SCALANCE XM-400/XR-500 Command Line Interface (CLI)