Ports - Siemens SCALANCE XM-400 Configuration Manual

Simatic net industrial ethernet switches command line interface (cli)
Hide thumbs Also See for SCALANCE XM-400:
Table of Contents

Advertisement

Syntax
Call the command without parameters:
no name
Result
The name of the VLAN is deleted.
Further notes
You assign the VLAN a name with the command
6.1.4.3

ports

Description
With this command, you generate a list that specifies the behavior of the interfaces and
replaces the existing VLAN configuration.
● Member Port (tagged port)
The interface is added permanently to the list of incoming and outgoing connections.
Tagged and untagged frames are transferred.
● Untagged Port
The interface transfers untagged frames. If the VLAN ID (PVID) is set, incoming untagged
frames are given a tag with the VLAN ID specified there. Received frames with a VLAN
ID are forwarded according to the VLAN ID. With outgoing frames, the tag with the VLAN
ID is removed.
● Forbidden Ports
The "tagged port" and "untagged port" you specify with this command are used for outgoing
data traffic.
Requirement
You are in the VLAN configuration mode.
The command prompt is as follows:
cli(config-vlan-$$$)#
SCALANCE XM-400/XR-500 Command Line Interface (CLI)
Configuration Manual, 06/2016, C79000-G8976-C252-11
This interface is not used for communication in a VLAN.
.
name
Network structures
6.1 VLAN
219