Layer 3 functions
9.3 OSPFv3 (IPv6)
Requirement
● The interface is an IPv6 interface.
● You are in the Interface configuration mode
The command prompt is as follows:
cli(config-if-$$)#
Syntax
Call up the command with the following parameters:
ipv6 ospf hello-interval <interval>
The parameter has the following meaning:
Parameter
interval
Result
The interval is specified.
Further notes
You enable OSPFv3 routing with the
You reset the interval to the default with the
You display the configuration with the
9.3.4.6

no ipv6 ospf hello-interval

Description
With this command, you reset the interval to the default value.
Note
This command is available only with layer 3.
606
Description
Interval in seconds
ipv6 router ospf
show ipv6 ospf interface
Range of values / note
1 ... 65535
Default: 10
The routers located on the same link must have the
same interval.
command.
no ipv6 ospf hello-interval
command.