Result
The blocking of broadcast frames is disabled.
Further notes
You enable the blocking of broadcast frames with the
3.1.13.5

duplex

Description
Electrical interfaces can be operated in full duplex mode or half duplex mode. The options
here depend on the connected device.
Optical connections are always operated in full duplex mode since they have a fiber for each
transmission direction.
With this command, you configure the duplex mode of an interface. The same mode must be
set for connected interfaces.
Requirement
● Autonegotiation is disabled.
● You are in the Interface configuration mode of an electrical interface.
The command prompt is as follows:
cli(config-if-$$$)#
Syntax
Call up the command with the following parameters:
duplex {full|half}
The parameters have the following meaning:
Parameter
full
half
Result
The duplex mode of the interface is configured.
SCALANCE XM-400/XR-500 Command Line Interface (CLI)
Configuration Manual, 06/2016, C79000-G8976-C252-11
Description
The Interface will be operated in full
duplex mode.
The Interface will be operated in half
duplex mode
command.
broadcast-block
Range of values / note
Default:
full
-
Configuration
3.1 System
95