No Radius-Server - Siemens SCALANCE XM-400 Configuration Manual

Simatic net industrial ethernet switches command line interface (cli)
Hide thumbs Also See for SCALANCE XM-400:
Table of Contents

Advertisement

Security and authentication
11.2 RADIUS client
Parameter
key
secret-key-string
primary
login
dot1x
login-dot1x
test
For information on addresses and interfaces, refer to the section "Addresses and interface
names (Page 42)".
If optional parameters are not specified when configuring, the default values apply.
Note
Primary server
In a network, only one RADIUS server can be selected as the primary server.
If you select a RADIUS server as the primary server, this replaces the server that previously
had the role of primary server.
11.2.2.5

no radius-server

Description
With this command, you delete a RADIUS server entry on the RADIUS client.
Requirement
You are in the Global configuration mode.
The command prompt is as follows:
cli(config)#
822
Description
Keyword for the key for communication
between the authenticator and the
server
Value for the key
Identifies the RADIUS server as prima-
ry server
The server is used only for the login
authentication.
The server is used only for the 802.1X
authentication.
The server is used for both authentica-
tion procedures.
Tests whether or not the specified
RADIUS server is available. At the
same time you can create a new
RADIUS server and run the test.
SCALANCE XM-400/XR-500 Command Line Interface (CLI)
Range of values / note
-
127 characters
Default: "default"
-
-
-
Default setting
-
Configuration Manual, 06/2016, C79000-G8976-C252-11

Advertisement

Table of Contents
loading

Table of Contents