Configuration
3.5 PoE
poe pse <integer (1-4)> usage <integer (1-100)>
The parameters have the following meaning:
Parameter
integer
integer
Result
The value for "Usage Threshold" is configured.
3.5.2.4

no poe pse usage

Description
With this command, you reset the parameter "Usage Threshold" to the default value.
Requirement
You are in the Global configuration mode.
The command prompt is as follows:
cli(config)#
Syntax
Call up the command with the following parameters:
no poe pse <integer (1-4)> usage
The parameter has the following meaning:
Parameter
integer
Result
The parameter "Usage Threshold" is reset to the default value.
132
Description
Number of the PSE
Value for "Usage Threshold" as a
percentage.
Description
Number of the PSE
SCALANCE XM-400/XR-500 Command Line Interface (CLI)
Range of values / note
1 ... 4
1 ... 100
Default: 80%
Range of values / note
1 ... 4
Configuration Manual, 06/2016, C79000-G8976-C252-11

Advertisement