Network protocols
7.9 SMTP Client
7.9.2.2

no smtp-server

Description
With this command, you delete an SMTP server entry.
Requirement
You are in the EVENTS configuration mode.
The command prompt is as follows:
cli(config-events)#
Syntax
Call up the command with the following parameters:
no smtp-server { ipv4 <ucast_addr> | fqdn-name <FQDN)> | ipv6 <ip6_addr>}
The parameters have the following meaning:
Parameter
ipv4
ucast_addr
fqdn-name
FQDN
ipv6
ip6_addr
For information on addresses and interfaces, refer to the section "Addresses and interface
names (Page 42)".
Result
The SMTP server entry is deleted.
Further notes
You configure an SMTP server entry with the
7.9.2.3

sender mail-address

Description
With this command, you configure the e-mail name of the sender.
416
Description
Keyword for an IPv4 address
IPv4 address of the SMTP server
Keyword for a domain name
Domain name (Fully Qualified Domain
Name)
Keyword for an IPv6 address
IPv6 address of the SMTP server
smtp-server