Functions specific to SCALANCE
4.4 Signaling contact
4.4.2.1
signaling contact mode
Description
With this command, you specify the reaction of the signaling contact.
Requirement
You are in the Global configuration mode.
The command prompt is as follows:
cli(config)#
Syntax
Call up the command with the following parameters:
signaling-contact mode {conventional | aligned}
The parameters have the following meaning:
Parameter
conventional
aligned
Result
The reaction of the signaling contact is specified.
Further notes
You display the setting with the
4.4.2.2
signaling-contact status
Description
With this command, you close or open the signaling contact.
Requirement
You are in the Global configuration mode.
The command prompt is as follows:
cli(config)#
152
Description
An error/fault is displayed by the fault LED and the signaling contact is
opened. When the error/fault state no longer exists, the fault LED goes off
and the signaling contact is closed.
The way the signaling contact works does not depend on the error/fault that
has occurred. The signaling contact can be opened or closed as required
by user actions.
show signaling contact
SCALANCE XM-400/XR-500 Command Line Interface (CLI)
command.
Configuration Manual, 06/2016, C79000-G8976-C252-11