11.1 User management
Syntax
Call the command without parameters:
whoami
Result
The user name of the logged in user is displayed.
11.1.4

Commands in the global configuration mode

This section describes commands that you can call up in the Global configuration mode.
In Privileged EXEC mode, enter the
Commands relating to other topics that can be called in the Global configuration mode can
be found in the relevant sections.
You exit the Global configuration mode with the
Privileged EXEC mode again.
11.1.4.1

password policy

Description
With this command you specify which password policy will be used when assigning new
passwords.
Requirement
You are in the Global configuration mode.
The command prompt is as follows:
cli(config)#
Syntax
Call up the command with the following parameters:
password policy < low | high >
The parameters have the following meaning:
Parameter
low
high
806
configure terminal
Description
Password policy: Low
Password policy: High
command to change to this mode.
or
command and are then in the
end
exit
Range of values / note
Password length: at least 6 characters
Password length: at least 8 characters
at least 1 uppercase letter
at least 1 special character
at least 1 number