Layer 3 functions
9.4 VRRPv2 (IPv4)
9.4.4.12

vrrp timer

Description
With this command, you specify the time interval after which a virtual router with the "Master"
status sends an advertisement packet again.
Note
This command is available only with layer 3.
Requirement
● An IPv4 address is assigned to the virtual router.
● You are in the VRRP Interface configuration mode
.The command prompt is:
cli(config-vrrp-if)#
Syntax
Call up the command with the following parameters:
vrrp <vrid(1-255)> timer <interval(1-255)secs>
The parameters have the following meaning:
Parameter
vrid
interval
Result
The time interval is specified
Further notes
You configure a VRRP interface with the
You enable routing with VRRP with the
You reset the time interval to the default with the
You assign IP addresses to a virtual router with the
You show the interval with the
642
Description
ID of the virtual router
Time interval in seconds
interface
router vrrp
show vrrp interface - vrid
SCALANCE XM-400/XR-500 Command Line Interface (CLI)
Range of values / note
1 ... 255
1 ... 255
Default: 1 s
command.
command.
command.
no vrrp timer
vrrp associated-ip
command.
Configuration Manual, 06/2016, C79000-G8976-C252-11
command.