No Poe Active; Poe Custom Maxpwr - Siemens SCALANCE XM-400 Configuration Manual

Simatic net industrial ethernet switches command line interface (cli)
Hide thumbs Also See for SCALANCE XM-400:
Table of Contents

Advertisement

Configuration
3.5 PoE
3.5.3.2

no poe active

Description
With this command, you deactivate PoE for the interface in whose interface configuration
mode you are currently working.
Requirement
You are in the Interface Configuration mode of a PoE interface.
The command prompt is as follows:
cli(config-if-$$$)#
Syntax
Call the command without parameters:
no poe active
Result
PoE is deactivated for the corresponding interface.
3.5.3.3

poe custom maxpwr

Description
With this command you set the maximum power that a port makes available to supply a
connected device.
This value is taken into account when the function is enabled with the
active
Requirement
You are in the Interface Configuration mode of a PoE interface.
The command prompt is as follows:
cli(config-if-$$$)#
Syntax
Call up the command with the following parameter:
poe custom maxpwr <integer(0-30)>
134
command.
SCALANCE XM-400/XR-500 Command Line Interface (CLI)
Configuration Manual, 06/2016, C79000-G8976-C252-11
poe custom maxpwr