Rmon Alarm - Siemens SCALANCE XM-400 Configuration Manual

Simatic net industrial ethernet switches command line interface (cli)
Hide thumbs Also See for SCALANCE XM-400:
Table of Contents

Advertisement

12.5.2.3

rmon alarm

Description
With this command, you configure an alarm for monitoring a MIB variable. The variable is
checked at specific intervals to determine whether or not it has exceeded or fallen below
threshold values. Events are assigned to these occurrences.
Requirement
You are in the Global configuration mode.
The command prompt is as follows:
cli(config)#
Syntax
Call up the command with the following parameters:
rmon alarm <alarm-number><mib-object-id(255)>
<sample-interval-time(1-65535)>
{absolute|delta}
rising-threshold<value(0-2147483647)>[risingevent-number(1-65535)]
falling-threshold<value(0-2147483647)>[fallingevent-number(1-65535)]
[owner<ownername(127)>]
The parameters have the following meaning:
Parameter
alarm-number
mib-object-id
sample-interval-
time
absolute
delta
rising-threshold
value
risingevent-number
falling-threshold
value
fallingevent-number
owner
ownername
SCALANCE XM-400/XR-500 Command Line Interface (CLI)
Configuration Manual, 06/2016, C79000-G8976-C252-11
Description
Number of the alarm
Name of the MIB variable
Interval for the check [s]
The current absolute value of the moni-
tored MIB is evaluated
The difference between the current and
the previous value of the monitored
MIB is evaluated
Keyword for threshold value for rising
or high variable values
Relevant threshold value
Event number for this
Keyword for threshold value for falling
or low variable values
Relevant threshold value
Event number for this
User to which the alarm is assigned
User name of the user
Diagnostics
12.5 RMON
Range of values / note
1 ... 250
max. 255 characters
1 ... 65535
-
-
-
0 ... 2147483647
1 ... 65535
-
0 ... 2147483647
1 ... 65535
-
max. 127 characters